  • 2000L/H Softener Hardness TDS Remove for Boiler Industrial Water Filter
  • 2000L/H Softener Hardness TDS Remove for Boiler Industrial Water Filter
  • 2000L/H Softener Hardness TDS Remove for Boiler Industrial Water Filter
  • 2000L/H Softener Hardness TDS Remove for Boiler Industrial Water Filter
  • 2000L/H Softener Hardness TDS Remove for Boiler Industrial Water Filter
  • 2000L/H Softener Hardness TDS Remove for Boiler Industrial Water Filter
Find Similar Products

Basic Info.

Model NO.
KYRO-2000
Capacity
2000 Liters
Imported RO Membrane
USA Dow Lcle-4040
Multiple -Choice Control Valve
Automatic or Manual
Recovery Rate
50%-75%
Desalination Rate
97%
Membrane Vessel
FRP or Stainless Steel
Feed Water TDS
<2000mg/L
Function
Water Purifying
Warranty
1 Year
High Pressure Pump
Cnp
Transport Package
Standard Packing
Specification
2000L/H
Trademark
Kaiyuan
Origin
China
HS Code
8421299090
Production Capacity
2000L/H

Product Description

2000L/H Softener RO System Hardness TDS Remove For Boiler Industrial Water Filter

1. First stage pretreatment.(Sand filter)

The use of multi-medium quartz sand filters, main purpose is to remove the water contains sediment, manganese, rust, colloid material, mechanical impurities, suspended solids and other particles in the above 20UM of substances hazardous to health.

2. Second stage pretreatment (Carbon filter)

Activated carbon filters used to remove the pigment in the water, smell, a large number of chemical and biological organisms, reducing the residual value of water and pesticide pollution and other harmful pollutants.

3. Third stage pretreatment (Resin softener)

Cationic resin used for water softening, primarily to remove hardness of water. So as to effectively prevent the reverse osmosis membrane fouling. System can automatically recoil, and so is red.

4. The basic working principle of softener RO system

a. Using a special high-pressure water pump, the raw water is added to a pressure of 6-20 kg, so that the raw water permeates through the reverse osmosis membrane with a pore diameter of only 0.0001 μm under the action of pressure.
b. Chemical ions and bacteria, fungi, virions can not pass, with the discharge of wastewater, only allow water molecules and solvents less than 0.0001 microns to pass.
c. The security filter is equipped with a filter element with a filter aperture of 5μm. These filters filter out any particles larger than 5μm.
d. The more common type of permeable membrane is a polyamide membrane, and the membrane type is a wound composite membrane. The membrane has a salt removal rate of 99.5%.

e. Because the RO membrane is susceptible to the pH value, residual chlorine and water temperature in the water, the RO membrane has strict requirements on the water quality before the operation:

PH value: 3~10
Residual chlorine value: <0.1mg/L
SDI15 value: <5.0
Water temperature: 4~39 °C

 

Using softener RO system advantage

1. After the machine is turned on, the device realizes the automatic film rinsing function, and the rinsing time is adjustable from 2 to 10 minutes.
2. The equipment has a waste water return device, which can be used for secondary use of water to improve water utilization and save water costs.
3. Low-voltage protection system, when the source water pressure is insufficient or passive water, the equipment will automatically stop, protecting the high-pressure pump and equipment safety.
4. The equipment can be automatically shut down after the water tank is full.
5. The equipment is equipped with a cleaning and maintenance system, which can regularly clean and maintain the equipment and prolong the service life of the reverse osmosis membrane for 3-5 years.
6. The equipment adopts stainless steel frame structure to achieve no sanitary corners, and the equipment is non-corrosive. It is still as new as 10-20 years.
7. The two-stage reverse osmosis equipment is equipped with multi-way regulating valve, which can realize double-stage effluent, single-stage effluent or single-stage effluent at the same time, so that the water quality is diversified.
8. Reverse osmosis equipment can be used with mineral water equipment (mountain spring water equipment) to reduce investment costs and improve water resource utilization.
9, the equipment can basically achieve 24-hour unattended operation.
10. An online water quality detector is available to observe the water quality at any time.

 

Softener RO system consumables

There are several kinds of consumables you need to replace regularly. (for 2000LPH)

a. Quartz sand: replaced about every 15-24 months. 50kg/bag,450kg/set

b. Activated carbon: replaced about every 15-24 months. 25kg/bag, 125kg/set

c. Resin: replaced about every 15 months. 25L/bag, 225L/set

d. PP Filter cartridge: replaced about every 1 month. 7pcs/set

e. Ro membrane: replaced about every 2 year. 8pcs/set

We suggest you buy 1- 2 years of PP filter cartridges together with machine.

Because these PP filter cartridges need to replace every month.


Softener RO system Processing
Process: raw water + raw water tank(client supply) + raw water pump + quartz sand filter + activated carbon filter + water softener/chemical dosing system(optional) + security filter + high pressure pump + ro system + pure water tank((client supply)) + UV sterilizer(ozone generator) + precision filter + water supply point
 
Softener RO system Show
2000L/H Softener Hardness TDS Remove for Boiler Industrial Water Filter
2000L/H Softener Hardness TDS Remove for Boiler Industrial Water Filter

Thank you so much for your value time. Any questions please click "contact now" send us inquiry !We will reply you within 24 hours. Tel/ whatsApp/ wechat:  

Guidelines for getting a proper quotation:

Tell us the raw water/source of water

Provide water analysis report

Required production capacity( 500 liters per hour, 1000liters per hour…)

What's the pure water used for( drinking, bottle water or industrial use…)

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier