Water Treatment Plant /Iron Manganese Removal Filter /15tph RO System

Product Details
Customization: Available
Certification: ISO9001, CE, SGS
Salt Rejection Rate: 99.0%
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
20
Year of Establishment
2008-12-02
  • Water Treatment Plant /Iron Manganese Removal Filter /15tph RO System
  • Water Treatment Plant /Iron Manganese Removal Filter /15tph RO System
  • Water Treatment Plant /Iron Manganese Removal Filter /15tph RO System
  • Water Treatment Plant /Iron Manganese Removal Filter /15tph RO System
  • Water Treatment Plant /Iron Manganese Removal Filter /15tph RO System
  • Water Treatment Plant /Iron Manganese Removal Filter /15tph RO System
Find Similar Products

Basic Info.

Model NO.
KYRO-15TPH
Application
Industry
Capacity
15000 Liters
Name
Iron Manganese Removal Filte 15tph RO System
RO Membrane
USA Filmtec Dow(DuPont) Bw30-400ig
Voltage
220V/ 380V/ 415V, 50Hz/ 60Hz, 3pH
Multiple -Choice Control Valve
Automatic or Manual
Membrane Vessel
FRP or Stainless Steel
Recovery Rate
50%-75%
Feed Water TDS
<2000mg/L
Function
Water Purifying
Desalination Rate
99%
High Pressure Pump
Cnp
Transport Package
Standard Packing
Specification
15000L/H
Trademark
Kaiyuan
Origin
China
HS Code
8421299090
Production Capacity
15000L/H

Product Description

Water Treatment Plant /Iron Manganese Removal Filter /15TPH RO System
 

Input Iron< 15mg/L, Manganes<10mg/L.

Output Iron< 0.03mg/L, Manganes<0.01mg/L.

Reach drinking water standard.

Manganese sand filter mainly used to reduce the water content of iron and manganese, ferromanganese total, some of our groundwater iron up 5 ~ 10mg / L, also have high to 20 ~ 30mg / L, manganese of up to 0.5 ~ 2.0mg / L, more than 2mg / L or each high 5 ~ 10mg / L is also a discovery . China's "drinking water standards" requirement, the iron content in drinking water should not exceed 0.3mg / L, manganese content of not more than 0.1mg / L, over time must be addressed.

Manganese sand filter is a strong antioxidant , to oxidation ferrous up oxidation role in water , usual used in drinking water in addition to iron and manganese removal filter device, groundwater for removing iron and manganese purification of water use.

The Manganese sand filter Advantages:
1. High-quality raw material and great grain density;
2. High mechanical strength and stable chemical property;
3. Large specific surface area and good adsorption;
4. High chemical activity and good oxidation and catalysis effect;
5. Great effect on deferrization and demanganization;
6. Harmless and long service life.

How it works:

Fe (Mn) of groundwater through aeration or adding an oxidizing agent, the water iron (manganese) ions begin oxidized manganese sand filter when the water flows through when contact occurs during filtration and the filter surface oxidation biochemical and physical adsorption interception , so that the water iron (manganese) ions precipitate removed. Especially in the treatment of micro process polluted groundwater manganese, iron, manganese bacteria not only can effectively remove, while ammonia as a nutrient source to the water for metabolism, the participation of the other bacteria, and to achieve the effect of ammonia.

Principle:

Iron and manganese oxidation reaction in the following manner:
Iron oxide: Air: 4Fe2 + +3 O2 +6 H2O = 4Fe (OH) 3 ↓
Manganese sand MnO Mn2O7 + Fe2 + + O2 + 6 H2O = 3MnO2 +4 Fe (OH) 3 ↓
Manganese oxide: Mn2 + + O2 = MnO2 ↓
Manganese sand Mn2 + + MnO2 • H2O = MnO2 • MnOH2O +2 H +

Reverse Osmosis System process:

Raw water tank→ raw water pump→manganese sand filter→quartz sand filter →activated carbon filter→security filter→high pressure pump→ro system→pure water tank+UV sterilizer(ozone generator) +precision filter+ water supply point
Water Treatment Plant /Iron Manganese Removal Filter /15tph RO System
Water Treatment Plant /Iron Manganese Removal Filter /15tph RO System
Water Treatment Plant /Iron Manganese Removal Filter /15tph RO System
Water Treatment Plant /Iron Manganese Removal Filter /15tph RO System
Water Treatment Plant /Iron Manganese Removal Filter /15tph RO System
Water Treatment Plant /Iron Manganese Removal Filter /15tph RO System
Water Treatment Plant /Iron Manganese Removal Filter /15tph RO System
Thank you so much for your value time.Any questions please click "contact now" send us inquiry !We will reply you within 24 hours.   

 
Guidelines for getting a proper quotation
Tell us the raw water/source of water
Provide water analysis report
Required production capacity( 500 liters per hour, 1000liters per hour…)
What's the pure water used for( drinking, bottle water or industrial use…)


♥ Hello!  Want to know more? Welcome to contact me   ^_^
Your inquiry will get our prompt reply! 
  

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier