High performance Deep Well salt underground Water Purification 3000LPH
Design basis and treated water standard:
1. Design Basis
1.1 Produced water's application: Bottle drinking water, pure water
1.2 The capacity of produced water: 3000L /H
1.3 System Configuration: Pretreatment + One Stage Reverse Osmosis Desalination System.
1.4 Designed recovery: 50-65%.
1.5 Rejection rate: ≥ 97%
1.6Voltage: 3 phases, 380V, 50Hz; Power: 5KW (Can be customized at your country's voltage, please tell us about it when ordering)
1.7 Operation Process: Automatic Running


System requirements:
2.1 Inlet pipelines: Inlet pipe connected with the raw water tank entrance.
2.2 Cable: According to the calculated capacity of electric power, the user should send it on the control cabinet.
2.3 Outlet water pipelines: From pure water tank to the pure water using point.
2.4 Concentrated Water Treatment: Discharge to the wastewater pool (user considered).
2.5 Water temperature: 5-35
Working Process:
Water Source - Raw Water Tank - Booster Pump - Sand Filter - Carbon Filter - Security Filter - High Pressure Pump - RO Components - Pure Water Tank
Features of Electric Control:
1)Inlet low pressure protection switch of high-pressure pump:
Linkage with the high-pressure pump, pressure below the set value, high-pressure pump will stop running.
2) The membrane inlet high pressure protection switch:
Linkage with the high-pressure pump, if operated high pressure too high, the membrane will be easy get blocked, even penetrated. When the membrane system operating pressure exceeds the setting value, the high-pressure pump will stop running.
3) The reverse osmosis unit equipped with low pressure automatic flush valve:
Linkage with the high-pressure pump, set by the time relay, when the reverse osmosis unit start to work, the system auto startup, washing the film surface with large-flow, so the sediments on membrane surface washed away in time, to ensure the normal operation of membrane.
4) Raw water tank / pure water tank high and low level control switch
The raw water pump / high pressure pump linkage, the raw water tank at low level, the raw pump automatic shutdown for protection, when pure water tank full, high-pressure pump to stop.